Warn Industrial Catalog - 2020

SERIES G2 9 DC 12V/24V

SERIES G2 12 DC 12V/24V

SPECIFICATIONS

SPECIFICATIONS

Part number: 104320 (CCW, 12V), 104325 (CW, 12V), 104909 (CCW, 12V, Spydura Pro Rope), 104340 (CCW 24V), 104345 (CW 24V) Maximum pulling force: 9,000 lbf. (4082 kgf) Drum barrel diameter: 4” (101.6 mm) Drum flange diameter: 8.24” (209.3 mm) Distance between flanges: 9.95” (252.7 mm) Maximum wire rope recommended: 1/2” (12.7 mm)

Minimum rope breaking strength: 15,100 lbf. (6,849 kgf) Evaluated rope diameter: 3/8” (9.5 mm) Maximum layers of wire rope: 4 layers with 3/8” rope Gear ratio: 212:1 Electric motor: 12V or 24V Approximate weight (winch only): 96.9 lbs. (44.0 kg) Standards compliance: SAE J706, CE Compliant

Part number: 104420 (CCW, 12V), 104425 (CW, 12V), 104912 (CCW, 12V, SpyduraPro Rope), 104440 (CCW, 24V), 104445 (CW 24V) Maximum pulling force: 12,000 lbf. (5443 kgf) Drum barrel diameter: 4” (101.6 mm) Drum flange diameter: 8.24” (209.3 mm) Distance between flanges: 9.95” (252.7 mm) Maximum wire rope recommended: 1/2” (12.7 mm)

Minimum rope breaking strength: 20,400 lbf. (9,253 kgf) Evaluated rope diameter: 7/16” (11 mm) Maximum layers of wire rope: 4 layers with 7/16” rope Gear ratio: 321:1 (12V) 266:1 (24V) Electric motor: 12V or 24V Approximate weight 12V (winch only): 97.0 lbs. (44.0 kg) Approximate weight 24V (winch only): 98.0 lbs. (44.5 kg) Standards compliance: SAE J706, CE Compliant

PERFORMANCE DATA BY LAYER

PERFORMANCE DATA BY LAYER

12V No Load Line Speed

24V No Load Line Speed

12V No Load Line Speed

24V No Load Line Speed

Line Load

Line Load

Drum Layer

Drum Layer

lbf

kgf

kN 40

ft/min

m/min

ft/min

m/min

lbf

kgf

kN

ft/min

m/min

ft/min

m/min

1

9000 7683 6702 5943

4082 3485 3040 2696

25.9 28.1 30.3 32.6

7.9 8.6 9.2 9.9

29.5 32.0 34.6

9.0 9.8

1

12000 10024 8606 7540

5443 4547 3904 3420

53.4 44.6 38.3 33.5

18.6 20.4 22.3 24.1

5.7 6.2 6.8 7.3

24.8 27.2 29.7 32.1

7.6 8.3 9.0 9.8

2 3 4

34.2 29.8 26.4

2 3 4

10.5 11.3

37.1

FIRST LAYER PERFORMANCE DATA

FIRST LAYER PERFORMANCE DATA

12V Current Draw

24V Current Draw

12V Duty Cycle

24V Duty Cycle

12V Current Draw

24V Current Draw

12V Duty Cycle

24V Duty Cycle

12V Line Speed (At Load)

24V Line Speed (At Load)

12V Line Speed (At Load)

24V Line Speed (At Load)

Line Load

Line Load

lbf

kgf

Amps

Amps 46.7 85.8 117.5 146.7 176.8 209.5 235.7

ft/min

m/min

ft/min

m/min min/10min min/10min

lbf

kgf

Amps

Amps

ft/min

m/min

ft/min

m/min min/10min min/10min

0

0

84.2

18.6 10.6

5.7 3.2 2.3 1.9 1.6 1.2 1.2

24.8 14.4 10.7

7.6 4.4 3.3 2.9 2.5 2.1 2.0

3:00 2:00 1:20 1:00 0:40 0:25 0:20

4:00 2:45 1:50 1:10 0:50 0:30 0:20

0

0

92.3

48

25.9 15.4

7.9 4.7 3.4 2.8 2.3 1.8 1.7

25.9 18.4 14.1 12.4

9.0 5.6 4.3 3.8 3.4 2.8 2.7

5:00 3:15 2:00 1:20 0:50 0:30 0:20

4:15 2:45 1:40 1:10 0:40 0:30 0:20

2000 4000 6000 8000 10000 12000

907 1814 2722 3629 4536 5443

158.6 215.7 269.7

1500 3000 4500 6000 7500 9000

680 1361 2041 2722 3402 4082

160.3 222.7 283.1 342.5 398.8

83.2 113.6 142.6 171.5 198.9 221.4

7.4 6.1 5.1

11

9.5 8.3 6.9 6.6

9.1 7.5 6.0 5.6

326

11

381.2 422.8

4

9.3 8.9

3.9

447

09 warn.com