PullzAll - Service Guide - 986765.A2

Motor does not run. Faulty Trigger Switch

Repair or replace Switch

Defective Motor

Replace Motor

Loose connection of the Wires to be Motor terminals.

Secure the Motor terminal and Wires.

1.6 Electrical sparks appear around Motor.

Switch held in power-in position while PullzAll is stalled.

Replace Wiring harness PullzAll Motor.

1.7 Wiring harness insulation has melted. 1.8 PullzAll makes squeaking / high pitch noise.

Poor installation caused Wire insulation to be rubbed off or cut, causing direct short.

Replace Wiring harness.

Drum Bushing not lubricated. Grease Drum Bushings.

1.10 Malfunctioning

Not operating correctly.

Cease operation. Diagnose, Repair or Replace.

INSPECTION

VISUAL INSPECTION:

• While disconnecting the connectors, never pull the wiring Harnesses. Unlock the connector first and then pull them apart by holding connectors themselves.

• While connecting connectors, also hold connectors and put them together until they lock securely (a click is heard).

• While Installing the Wiring Harness, fix it with clamps so that no slack is left.

• While using a tester for checking continuity or measuring voltage, be sure to insert the tester probe from the wire harness side.